Brand Name : Shenglin

Model Number : MD series

Certification : CE

Place of Origin : China

MOQ : 1 pcs

Price : 1550~7000USD

Payment Terms : T/T, Western Union

Supply Ability : 1000 PCS/month

Delivery Time : 15~20 days

Packaging Details : Plywood case

COP : 4

Compressor : Panasonic or Copeland brand

Heat exchanger type : One fin type, one coil type

Application : House, Appartment, School, Hospital, Villa

Supply power : 380V/3PH/50Hz

Refrigerant : R22/R417A/R404A/R407C/R410A

Working ambient temperature : -15 ° C ~ 45 ° C

Warranty : 1 Year

Installation : Freestanding

Heating capacity range : 15~84kW

Water outlet temp. : 55° C

Contact Now

Air Source Heat Pump Hot Water Type

Technical paramater:

Air source heat pump MODEL Unit MD40D
Average heating input power KW 3.78
Rated heating capacity KW 15
Hot water supply L/h 350
Rated heating input current A 9
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 55
Pipe size DN 25
Air source heat pump MODEL Unit MD50D
Average heating input power KW 4.6
Rated heating capacity KW 18.6
Hot water supply L/h 400
Rated heating input current A 9
Max outlet water temp C 60
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 170
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Article Parameter
Air source heat pump MODEL Unit MD60D
Average heating input power KW 5.2
Rated heating capacity KW 21
Hot water supply L/h 500
Rated heating input current A 12
Max outlet water temp 60
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 180
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 6000L/h
Water pressure down Kpa 48
Pipe size DN 25
Air source heat pump MODEL Unit MD100D
Average heating input power KW 9.2
Rated heating capacity KW 36
Hot water supply L/h 800
Rated heating input current A 18
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 310
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Air source heat pump MODEL Unit MD150D
Average heating input power KW 11
Rated heating capacity KW 42
Hot water supply L/h 1000
Rated heating input current A 24
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 340
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 12000L/h
Water pressure down Kpa 54
Pipe size DN 32
Article Parameter
Air source heat pump MODEL Unit MD200D
Average heating input power KW 19
Rated heating capacity KW 72
Hot water supply L/h 1600
Rated heating input current A 35
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Air source heat pump MODEL Unit MD300D
Average heating input power KW 22
Rated heating capacity KW 84
Hot water supply L/h 2000
Rated heating input current A 40
Max outlet water temp 60
Power V/Hz 380V/50
Noise Db(a) 70
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 750
Working air temp range (-15℃)—45℃
compressor Type Copeland
Air source heat exchanger Type Finned heat exchange
Fan Type axial flow fan
Hot water side heat exchange Type Coil heat exchanger
Water flow L/H 25000L/h
Water pressure down Kpa 60
Pipe size DN 50

Spare parts:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Heat exchanger type A: fin heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Heat exchanger type B: coil heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Heat exchanger type C: plate heat exchanger
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Electric expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Relay
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Senssor connector
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Liquid, gas separator
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Sensor
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Thermal expansion valve
MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Control panel

Simple installation diagram for air source:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units

Our factory:

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units


Product Tags:

Freestanding 84kW Air Source Heat Pumps

      

MD50D Air Source Heat Pumps

      

MD50D rooftop hvac units

      
Buy cheap MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units product

MD50D Freestanding 84KW Air Source Heat Pumps Hot Water Rooftop Hvac Units Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Shenglin M&E Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)